Combustion that measures itself, then improves

The difference between a burner that fires and a burner that performs is the intelligence wrapped around the flame. ThermoSys engineers that layer. Burner management, flame safeguard, precise sensing and continuous trim, integrated with LAMTEC technology and proven against measured baselines.

The intelligence layer of an engineered combustion system.

These are not accessories bolted onto a burner. Each element is specified into the safety chain and the control architecture from the first drawing.

CIN-01

Burner management systems

Flame safeguard and BMS design, sequencing, scanner selection and retrofit, with sign-off documentation.

CIN-02

Electronic fuel-air control

Compound control across the full firing range, replacing mechanical linkages with repeatable precision.

CIN-03

O₂ trim

Continuous flue-gas oxygen measurement holding combustion at its efficient, safe operating point.

CIN-04

CO and advanced optimisation

CO measurement pushing efficiency further where the application and the fuel allow it.

CIN-05

Flame monitoring

Reliable flame supervision engineered into the burner safety chain, matched to the fuel and the furnace.

CIN-06

Baselining and verification

Flue-gas analysis and fuel accounting before the work, and the same measurements after it.

A closed loop around the flame, running every second.

Combustion intelligence is a loop, not a gadget. Measure the flame, decide, actuate, and measure again, continuously, across the whole firing range.

01

Flame

The Process

02

Sensing

O₂ · CO · Temp

03

Analysis

Against Setpoint

04

Control

Fuel-Air Ratio

05

Actuation

Valves · Dampers · Fan

06

Burner Response

Corrected Firing

07

Trend

Logged · Visible

08

Verified Efficiency

Measured · Reported

Project-specific control philosophy and safety chain issued with every system

We never sell the range. We measure the plant.

Savings verified against baseline.

Optimisation without a baseline is a story. Follow one combustion optimisation from first measurement to final report and see why our numbers hold up.

  1. STEP 01
    Baseline

    The plant measured as found

    Flue-gas analysis and fuel accounting on the existing setup. This number is the honest starting line.

  2. STEP 02
    Tuning

    Combustion curves reset point by point

    Fuel and air corrected across the firing range with the analyser on the flue, not by ear.

  3. STEP 03
    Trim enabled

    O₂ trim holding the sweet spot

    Continuous oxygen measurement now corrects for air temperature, fuel variation and drift, every second the burner fires.

    3% Flue O₂
  4. STEP 04
    Verification

    Measured again, same method

    The same analysis repeated after the work. The difference between the two numbers is the result.

  5. STEP 05
    Report

    A result you can file

    Before and after figures, settings and curves documented and handed over. The saving has a paper trail.

Efficiency never outranks the safety chain.

Every optimisation lives inside a burner management system designed to shut the process down safely first and save fuel second. That order is not negotiable.

Explore Burner Management detail
Interlocks Designed in from the first drawing

Permissives, interlocks and trips engineered as part of the system, built to pass a safety audit.

Proven Every protective function tested

Functional testing and interlock proving recorded on site before the system is handed to production.

Documented Sign-off you can show an auditor

Cause and effect, test records and settings issued with every burner management system.

Sensing technology plus the people who commission it.

Industrial automation and combustion control equipment

Trusted

Efficiency measured, not claimed

Baselines before, analysis after, and a report in between. If the number did not move, we say so.

Engineer commissioning an industrial control system on site

Lasting

Watched after the invoice

Supported systems stay connected, so trim keeps trimming and drift gets caught between service visits.