Proven technology, engineered into one ThermoSys system.
ThermoSys works with three international technology partners: Rittal for enclosures and panel infrastructure, Ecostar for industrial and process burners, and Ecodense for commercial condensing boilers. We select, engineer, integrate, commission and support each one as part of a complete thermal system, with one team accountable from the first drawing to the final sign-off.
Three partners. One integrated system.
Each partner covers a different layer of a thermal plant: the panel that houses the controls, the burner and the boiler it fires. ThermoSys engineers all three together, so the interfaces between them are designed, tested and owned by one team instead of left to chance on site.
-
PT-01Germany
Rittal
Enclosures & panel infrastructure
Enclosures, power distribution and climate control that form the backbone of every ThermoSys control panel.
View Rittal -
PT-02Türkiye
Ecostar
Industrial & process burners
Monoblock, duoblock and process burners for gas, oil and dual-fuel duties, matched to each application.
View Ecostar -
PT-03Türkiye
Ecodense
Commercial condensing boilers
Premix condensing boilers and modular cascades for commercial heating and hot water.
View Ecodense
How the partners fit together
Most thermal plant problems start at the joins: a burner set up without its controls in mind, a panel that overheats, a boiler cycling because nobody tuned the whole loop. A ThermoSys system is built in layers, with each partner chosen for the job it does best and ThermoSys responsible for how they work together.
-
L-01
Panel, power and climate
Enclosures, busbar power distribution and cooling house the controls and keep them running in hot, dusty plant rooms.
-
L-02
Combustion
Burners matched to the fuel, firing range and combustion chamber of each boiler, furnace or dryer.
-
L-03
Heat generation
Condensing boilers and cascades that recover heat from the flue gas and follow the building's real demand.
-
ThermoSys · One sign-off
ThermoSys specifies the combination, engineers the interfaces, builds the panels, commissions the plant and stays on to support it. One team, accountable for the complete system.
Rittal enclosures, the backbone of every panel.
Rittal is a German manufacturer of enclosures, power distribution, climate control and IT infrastructure, founded in 1961 and part of the Friedhelm Loh Group. ThermoSys builds its burner management, motor control and automation panels on Rittal systems, and services and maintains Rittal enclosures and cooling units once they are in use. Every panel starts from a tested, documented platform with global support behind it, and stays in good working order long after handover.
Rittal has run its own South African subsidiary since 2004, which gives local projects direct access to the Rittal range.
- 1961
- Founded in Germany
- 2004
- South African subsidiary
- 5
- System areas
Rittal ranges ThermoSys specifies
R-01 / R-04-
R-01VX25 enclosure system and Ri4Power
A bayable large enclosure system with a continuous 25 mm pitch pattern on every axis, so mounting plates, rails and partitions fit wherever they are needed. Ri4Power adds low-voltage switchgear and power distribution on the same frame.
- Bayable
- 25 mm pitch
- Ri4Power
-
R-02AX and KX compact enclosures
Wall-mounted compact enclosures and small terminal boxes for local control stations, junction boxes and field panels, available in sheet steel and stainless steel.
- Wall-mount
- Stainless option
- Terminal boxes
-
R-03Blue e+ climate control
Hybrid enclosure cooling that pairs a speed-regulated compressor with a passive heat pipe. Rittal quotes energy savings of up to 75% against conventional units, which counts in hot plant rooms that run all year.
- Cooling units
- Service and Repair
- IoT interface
-
R-04RiLineX busbar power distribution
A 60 mm busbar system with click-in, tool-free components and continuous touch protection, for compact and safer power distribution inside the panel.
- 60 mm busbar
- Tool-free
- Touch-safe
How ThermoSys uses Rittal
Every ThermoSys panel is designed, built and tested in-house on a Rittal platform, then documented for the people who will maintain it. Once panels are in use, ThermoSys services and maintains the Rittal equipment and cooling units inside them.
- Burner management and combustion control panels built on Rittal enclosures
- Motor control centres and distribution boards on VX25 with Ri4Power
- Panel cooling sized for South African plant room temperatures
- Field stations and junction boxes in compact AX and KX enclosures
- Service and maintenance of Rittal cooling units, including filter and coil cleaning, condensate drain checks and fault finding
Ecostar industrial and process burners.
Ecostar has manufactured burners in Istanbul since 1967, with its own R&D centre, a factory in Çorlu and exports to more than 50 countries. The range runs from monoblock burners for boilers to duoblock industrial burners and high-temperature process burners, with low-NOx and low-CO versions.
ThermoSys matches each Ecostar burner to the fuel, firing range and heat demand of the application, then integrates it with the right controls so it performs as part of the whole plant.
- 1967
- Founded in Istanbul
- 50+
- Export countries
- 30
- R&D specialists
Ecostar burner ranges
E-01 / E-04-
E-01Monoblock burners
Self-contained burners with the fan built in, for hot water and steam boilers and hot air generators. Available for natural gas, LPG, light oil and dual fuel.
- Gas
- Light oil
- Dual fuel
-
E-02Duoblock industrial burners
Burners with a separate combustion air fan for larger boilers and heavier industrial duties, including heavy oil and combined-fuel operation.
- Separate fan
- Heavy oil
- Large boilers
-
E-03FPB and Gazoram process burners
FPB burners for industrial furnaces, melting and high-temperature baking, and Gazoram burners for continuous heating in production processes.
- Furnaces
- Melting
- High temperature
-
E-04Hot air generators
Direct-fired hot air for drying and process heating across a wide temperature range, on natural gas, light oil, heavy oil or dual fuel.
- Drying
- Process air
How ThermoSys uses Ecostar
The right burner is a combination of fuel, chamber, turndown and control. ThermoSys selects all four together.
- Burner selection matched to fuel, firing range and combustion chamber
- Burner replacements and fuel conversions on existing plant
- Integration with ThermoSys burner management panels
- Commissioning, emissions set-up and ongoing service
Ecodense condensing boilers and cascades.
Ecodense is Ecostar's condensing boiler brand, launched in 2016. Its premix boilers use stainless steel heat exchangers and a 5:1 modulation ratio, so output follows the building's real demand instead of cycling on and off.
ThermoSys engineers Ecodense boilers into complete commercial plant rooms, from a single wall-hung unit to a cascade of 16 boilers, with the pumps, controls and safety equipment designed around them.
- 2016
- Range launched
- 5:1
- Modulation ratio
- 16
- Boilers per cascade
Ecodense boiler ranges
D-01 / D-04-
D-01WT-S ONE wall-type boilers
Wall-hung condensing boilers from 35 to 65 kW for heating and domestic hot water, on natural gas or LPG.
- 35–65 kW
- Gas / LPG
-
D-02WT-SS wall-type boilers
Twelve outputs from 45 to 150 kW, with a heavier-gauge stainless steel heat exchanger and built-in magnetic residue protection. Up to 16 units cascade to 2,400 kW.
- 45–150 kW
- Cascade to 2,400 kW
-
D-03Cell Condense modular boilers
Modular floor-type condensing plant from 300 to 1,810 kW. If one module needs attention, the others keep running, so the building stays warm.
- 300–1,810 kW
- Modular
- Redundant
-
D-04Floor-standing condensing boilers
Premix floor-standing boilers for medium and high outputs, from 60 to 550 kW, with cascade connection for larger loads.
- 60–550 kW
- Cascade
How ThermoSys uses Ecodense
A condensing boiler only condenses when the system around it lets it. ThermoSys designs the whole plant room with that in mind.
- Boiler sizing and cascade design for commercial buildings
- Plant room integration with pumps, controls and building management
- Replacement of older non-condensing boilers
- Commissioning, servicing and connected support
Partner questions, answered.
What engineers and plant managers most often ask about the technology behind a ThermoSys system. If your question is not here, ask the team directly.
Ask an engineer-
Q-01Which technology partners does ThermoSys work with?
ThermoSys works with three international partners: Rittal (Germany) for enclosures, power distribution and panel climate control; Ecostar (Türkiye) for industrial and process burners; and Ecodense, Ecostar's condensing boiler brand, for commercial heating.
-
Q-02What does ThermoSys do with partner equipment?
ThermoSys selects the right equipment for each application, engineers the interfaces between burner, controls, panel and plant, builds the control panels, commissions the system on site and supports it afterwards. One team is accountable for how the complete system performs.
-
Q-03Are ThermoSys control panels built on Rittal enclosures?
Yes. Rittal enclosure systems form the backbone of ThermoSys control panels, from compact AX and KX enclosures for field stations to bayed VX25 systems with Ri4Power for motor control centres and power distribution. Panel cooling, such as Rittal Blue e+, is sized for the plant room it will run in.
-
Q-04What is the difference between Ecostar and Ecodense?
They come from the same manufacturer. Ecostar is the burner brand, founded in Istanbul in 1967, covering monoblock, duoblock and process burners and hot air generators. Ecodense is its condensing boiler brand, launched in 2016, covering premix wall-hung, floor-standing and modular boilers for commercial heating.
-
Q-05Which fuels can Ecostar burners fire?
Ecostar burners are available for natural gas, LPG, light oil, heavy oil and combined or dual-fuel operation, with low-NOx and low-CO versions. The right model depends on the fuel available on site, the firing range and the boiler, furnace or dryer it serves.
-
Q-06What sizes of Ecodense condensing boilers are available?
Ecodense wall-type boilers run from 35 to 150 kW per unit, and up to 16 WT-SS boilers can be cascaded to 2,400 kW. Floor-standing boilers cover 60 to 550 kW, and the modular Cell Condense range covers 300 to 1,810 kW.
-
Q-07Does ThermoSys support partner equipment after commissioning?
Yes. ThermoSys provides ongoing technical support, servicing and connected support for the systems it delivers, including the Rittal, Ecostar and Ecodense equipment inside them.
Put the right technology to work.
Tell us what you need to heat, fire or control. A ThermoSys engineer will recommend the right combination of partner technology and the shortest route to getting it running.
-
PR-01
Discuss a Project
New boilers, burners, panels or controls. Start with a conversation about the duty.
Talk to an engineer -
PR-02
Request a Panel Quotation
Rittal-based control panels, MCCs and distribution boards built to your drawings.
Send your specification -
PR-03
Book a Plant Assessment
Find out what O₂ trim, a burner upgrade or condensing plant could do for your site.
Book an assessment -
PR-04
Get Technical Support
Help with Rittal, Ecostar or Ecodense equipment already in service.
Contact support